It is conventional to install wall shields over fire resistant wall spacers.
Sheet metal wood stove heat shield.
Brickwork or stone behind a stove do not provide any reduction as brick or stone transfer heat.
A discussion started in 2004 but continuing through 2018.
Heat shield specifications for wood stoves pellet stoves the tan ceramic tile heat shield behind the woodstove and its flue in this photo was constructed by the author df in 1990 by bonding ceramic tile to a factory made fireproof heat shield board consisting of metal covering a fireproof cement board.
A fire resistant wall shield is necessary to eliminate the threat of fire.
Locate the studs in the wall behind the wood stove with a stud finder.
I ve installed it behind my new wood stove to 1 protect the wall behind it and 2 reflect the heat back into the room.
If you combine them with a 29 gauge sheet metal back you can cut the clearance by two thirds.
Bare wood or sheetrock walls around a wood stove are fire hazards.
Hi i have a 40 x60 26 gauge piece of sheet metal that i purchased from a machine shop in town.
Sheet metal heat shield for a wood stove.
Dwarf stove with currogated metal shield.
A brick stone or tile heat shield is.
By far the most effective heat shields are the air cooled type.
The wood stove heats up the metal and the metal spreads this heat over its entire surface area so that circulating air can keep everything sufficiently cool.
Your heat shields don t need to be made of the same materials.
These shields are constructed with a sheet of 24 gauge or thicker sheet metal or 1 2 or thicker cement board with 1 of air space behind the shield and around the perimeter to allow free air flow.
For instance you can have a floor heat shield of brick and wall heat shields of sheet metal.
The best wall shields help to radiate the heat from the stove into the room.
Wood stove heat shield ideas video installing a proper sheet metal shield behind a wood stove can reduce clearances by up to 66 in canada check your local code in your country.
The shield needs to be at least an inch from the wall and an inch off the floor and mechanically fastened.
Installing a sheet metal shield can reduce clearances by 67.